WHITE PAPER
Formlabs Logo

Form Cure L V1 time and temperature settings

Form Cure L V1 time and temperature settings

The Form Cure L helps 3D printed parts achieve their highest possible strength and stability. Optimal post-curing settings depend on equipment and the geometry of the part. Select the material type and version below to see the recommended Form Cure L time and temperature settings. To post-cure previous resin formulations with the Form Cure L, use the recommended time and temperature for the closest resin version.

Tip:

Over-curing is acceptable, unless otherwise stated. Increase the post-curing time for thick, bulky parts because they are slower to heat to the proper temperature.

For parts printed in a resin for a biocompatible application, follow the post-curing steps in the relevant instructions for use or application guide. For Formlabs Fast Cure settings, see the support article Fast Cure time settings.

Form Cure L V1 settings

Resin Post-cure setting Post-cure time Post-cure temperature
Alumina 4N Resin N/A4 N/A N/A
Black Resin V4/V4.1
Color Kit
Grey Resin V4/V4.1
White Resin V4/V4.1
Recommended1 30 min 60 °C
Full post-cure 60 min 60 °C
Black Resin V5
Clear Resin V5
Grey Resin V5
White Resin V5
Default1 5 min No heat
Enhanced mechanical properties 15 min 60 °C
BEGO™ VarseoSmileⓇ TriniQⓇ Resin Full post-cure2 Refer to the Instructions for Use for washing and post-curing instructions for this resin. Enter the item number (REF) from the resin cartridge label to access the IFU.
BioMed Amber Resin Full post-cure2 Refer to the Manufacturing Guide for washing and post-curing instructions for this resin.
BioMed Black Resin Full post-cure2 Refer to the Manufacturing Guide for washing and post-curing instructions for this resin.
BioMed Clear Resin Full post-cure2 Refer to the Manufacturing Guide for washing and post-curing instructions for this resin.
BioMed Durable Resin V1
BioMed Durable Resin V1.1
Full post-cure2 Refer to the Manufacturing Guide for washing and post-curing instructions for this resin.
BioMed Flex 50A Resin
(formerly BioMed Elastic 50A Resin)
Full post-cure2 Refer to the Manufacturing Guide for washing and post-curing instructions for this resin.
BioMed Flex 80A Resin Full post-cure2 Refer to the Manufacturing Guide for washing and post-curing instructions for this resin.
BioMed White Resin Full post-cure2 Refer to the Manufacturing Guide for washing and post-curing instructions for this resin.
Castable Resin Full post-cure3 240 min 60 °C
Castable Wax Resin
Castable Wax 40 Resin
N/A4 N/A N/A
Ceramic Resin N/A4 N/A N/A
Clear Cast Resin Recommended1 15 min 60 °C
Full post-cure 30 min 60 °C
Clear Resin V4/V4.1 Recommended1 15 min 60 °C
Full post-cure 30 min 60 °C
Color Resin V5 Full post-cure 5 min N/A
Custom Tray Resin Full post-cure2 Refer to the Manufacturing Guide for washing and post-curing instructions for this resin.
Dental LT Clear Resin V1 Full post-cure2 20 min 80 °C
Dental LT Clear Resin V2 Full post-cure2 Refer to the Manufacturing Guide for washing and post-curing instructions for this resin.
Dental LT Comfort Resin V1
Dental LT Comfort Resin V1.1
Full post-cure2 Refer to the Manufacturing Guide for washing and post-curing instructions for this resin.
Denture Base Resin V1 Full post-cure2 Refer to the Instructions for Use for washing and post-curing instructions for this resin.
Denture Base Resin V2 Full post-cure2 Refer to the Manufacturing Guide for washing and post-curing instructions for this resin.
Denture Teeth Resin Full post-cure2 Refer to the Instructions for Use for washing and post-curing instructions for this resin.
Draft Resin Better elongation 5 min No heat
Better UTS 5 min 60 °C
Durable Resin V2
Durable Resin V2.1
Full post-cure 60 min 60 °C
Elastic 50A Resin V1 Full post-cure5 20 min 60 °C
Flexible 50A Resin
(formerly Elastic 50A Resin V2)
Full post-cure6 30 min 70 °C
ESD Resin Full post-cure 60 min 70 °C
Fast Model Resin Default1 5 min No heat
Enhanced mechanical properties 15 min 60 °C
Flame Retardant Resin Better toughness 60 min 70 °C
Better HDT 120 min 80 °C
Flexible Resin Recommended1 15 min 60 °C
Full post-cure 60 min 60 °C
Flexible 80A Resin V1
Flexible 80A Resin V1.1
Soft Tissue Resin
Full post-cure 10 min 60 °C
Flexible 80A Resin V2 Default Cycle 16: 5 min
Cycle 2: 30 min
Cycle 16: No heat
Cycle 2: 70 °C
Grey Pro Resin Full post-cure7 15 min 80 °C
High Temp Resin V1 Recommended1 30 min 60 °C
Full post-cure 60 min 60 °C
High Temp Resin V2 Recommended8 120 min 80 °C
Thermal post-cure 180 min 160 °C
IBT Flex Resin Full post-cure2 Refer to the Manufacturing Guide for washing and post-curing instructions for this resin.
IBT Resin Full post-cure2 Refer to the Manufacturing Guide for washing and post-curing instructions for this resin.
Model Resin V2 Recommended1 30 min 60 °C
Full post-cure 60 min 60 °C
Model Resin V3 Full post-cure 5 min 60 °C
Permanent Crown Resin Full post-cure2 Refer to the Instructions for Use [EN] [EU] for washing and post-curing instructions for this resin.
Precision Model Resin Full post-cure 5 min 35 °C
Premium Teeth Resin Full post-cure2 Refer to the Manufacturing Guide for washing and post-curing instructions for this resin.
Rigid 4000 Resin Full post-cure 15 min 80 °C
Rigid 10K Resin V1
Rigid 10K Resin V1.1
Recommended7 60 min 70 °C
Thermal post-cure 125 min 90 °C
Silicone 40A Resin Full post-cure6 15 min preheat
45 min post-cure
60 °C
60 °C
Surgical Guide Resin Full post-cure2 Refer to the Manufacturing Guide for washing and post-curing instructions for this resin.
Temporary CB Resin Full post-cure2 Refer to the Instructions for Use for washing and post-curing instructions for this resin.
Tough 1000 Resin Recommended 60 min 70 °C
Tough 2000 Resin V1
Tough 2000 Resin V1.1
Tough 2000 Resin V2
Recommended 60 min 70 °C
Tough Resin V5 Recommended1 60 min 60 °C
Full post-cure 120 min 60 °C
Tough 1500 Resin V1
Tough 1500 Resin V1.1
Tough 1500 Resin V2
Full post-cure9 60 min 70 °C
True Cast Resin V1 Full post-cure 10 min N/A

1: Recommended post-cure settings achieve close-to-optimal mechanical performance and minimize post-cure time. Full post-cure settings achieve optimal mechanical properties. Use full post-cure settings when using materials for functional applications.
2: This post-cure setting ensures that parts achieve both biocompatibility and optimum mechanical properties. Read the Manufacturing Guide for a full description of the workflow.
3: Cure for 4 hours to increase the part strength. Increasing cure time may improve casting results, particularly for thicker parts, though casting success depends more on part geometry and casting process.
4: Does not require post-curing. After washing, allow parts to fully dry before firing/casting.
5: For parts printed with Durable Resin, the tensile modulus increases throughout the first hour of post-curing.
6: Post-cure parts completely submerged in room temperature water in a glass beaker (or other UV-transparent container).
7: There is no significant gain in properties after 15 minutes. There is only one recommended post-curing time.
8: There are several post-curing options for High Temp Resin V2 and Rigid 10K Resin. Refer to the technical data sheet to understand how different options affect mechanical properties, and choose the post-cure option that is best suited to the intended application. 
9: If parts printed with Tough 1500 Resin will be used for skin contact use, parts must be post-cured in a Form Cure L at 70 °C for 60 minutes.

Downloadable PDF