WHITEPAPER
Formlabs Logo

Delamination (SLA)

Delamination (SLA)

La delaminazione è un errore di stampa in cui gli strati polimerizzati di una stampa si separano l'uno dall'altro. Questo fenomeno può verificarsi su qualsiasi tipo di stampante 3D, anche se le cause sono uniche per ogni processo di stampa.

delamination

Indicatori visivi

  • Peeling or separation between printed layers
  • Pieces of cured parts floating in the resin tank

If a print has detached from the build platform, refer to the support article Non-adherence.

Cause comuni

Any of the following factors, or a combination of them, can cause delamination in prints:

  • Model orientation, layout, or support issues
  • A print that has been paused for an hour or longer
  • An older resin tank
  • Loose build platform
  • Contaminated optical surfaces
  • Debris or contamination in the resin tank

Passaggi per la risoluzione dei problemi

Il processo di risoluzione dei problemi consente di identificare i segnali e ridurre sistematicamente le cause alla base di un problema. Segui questi passaggi per verificare le possibili cause del problema di stampa, iniziando da quella più probabile.

Nota:

Assicurati di aver installato le versioni più aggiornate di firmware e PreForm. Per controllare la versione firmware della stampante, consulta l'articolo di assistenza Controllo della versione firmware delle stampanti SLA Formlabs. Per aggiornare la versione di PreForm, fai riferimento all'articolo Come si aggiorna PreForm? nelle FAQ.

Step 1: Check the model in PreForm

Lateral forces on the part during the print (for example, the pulling or sliding motion of the peel process on the Form 2) can disrupt the molecular bonding between layers and separate them. This separation occurs for two reasons:

  1. The part has a significant change in surface area between subsequent layers. Layers with large surface areas resist print forces better than layers with small surface areas, so a larger layer may separate from a smaller layer during the print. Reorient the part in PreForm to reduce the difference in surface area between neighboring layers.
  2. Sections of the part are free-hanging or lack adequate supports. In PreForm, look for areas shaded in red, and add supports to these areas.
  3. Suction cups, even small ones, can cause blowouts or delamination.
    1. Reorient models to avoid creating suction cups.
    2. Add drainage holes to models.
    3. Suction cups can inadvertently form when rafts partially overlap, leaving an enclosed space between them. Separate your models on the build platform to prevent this.
    4. Form 4 and Form 4L generation only: Enable the Cup Mitigation Enabled parameter in the Print Settings Editor to alleviate issues caused by suction cups.

Step 2: Check for pauses in printing

Extended pauses during the print can lead to delamination after the print resumes. For optimal dispensing, and to avoid long pauses during resin dispensing, use fuller resin cartridges when possible.

  1. Resolve any errors displayed on the touchscreen that pause the print.
  2. Enable notifications on Dashboard to receive text or email alerts for print interruptions as soon as they occur.

Step 3: Check the resin tank

Any damage or debris in or on the resin tank can block the laser at that location, preventing the resin directly above it from curing. Inspect the inside and underside of the tank for dirt, dust, and/or fingerprints. The bottom of the tank must be clean for the best print results.

  1. Inspect the resin tank for debris with the plastic scraper that comes with the Finish Kit or a similar tool. Apply minimal force to remove the cured resin. Avoid using the corners of the tool to dig under the print. Do not use metal tools to inspect the resin tank.
  2. Remove any failed prints and cured resin by printing a cleaning sheet.
  3. Filter the resin to remove any contamination or cured resin.
  4. Inspect the film at the bottom of the resin tank for scratches or wear. Excessive wear means the resin tank needs to be replaced.
  5. Inspect the underside of the film for dirt, dust, or fingerprints. Clean it with Formlabs recommended steps and supplies.
  1. Inspect the resin tank for debris with the tank tool.
  2. Remove any failed prints and cured resin using the tank tool.
  3. Alternatively, remove any failed prints and cured resin by printing a cleaning mesh.
  4. Filter the resin to remove any contamination or cured resin.
  5. Inspect the flexible film at the bottom of the resin tank for scratches or wear. Excessive wear means the resin tank needs to be replaced.
  6. Inspect the underside of the flexible film for dirt, dust, or fingerprints. Clean it with Formlabs recommended steps and supplies.
  1. Inspect the resin tank for debris with a scraper.
  2. Remove any failed prints and cured resin with the scraper, being careful not to gouge or cut the elastic layer at the bottom of the tank.
  3. Filter the resin to remove any contamination or cured resin.
  4. If using Resin Tank LT, skip this step. Inspect the elastic layer of the standard resin tank for clouding. Severe clouding means a standard resin tank needs to be replaced.
  5. Inspect the acrylic tank window on the underside of the resin tank for dirt, dust, cured resin, or fingerprints. Clean it with Formlabs recommended steps and supplies.

CONSIGLIO:

Per ottenere risultati ottimali, è necessario mantenere puliti e in buon ordine i serbatoi resina tra un lavoro di stampa e l'altro.

Step 4: Check the printer's optical surfaces

Any contamination, dust, or debris on the printer’s optical surfaces can cause the laser light to diffuse or weaken, resulting in a print failure. Contamination is most likely to occur on an exposed optical surface in the printer.

The optical surface most likely to be contaminated is the release texture, the top face of the Light Processing Unit (LPU). It prevents suction from forming between the resin tank film and the LPU, reducing peel forces between layers. Any contamination on the release texture can cause the backlight to diffuse or weaken, resulting in print defects.

  1. Remove any inserted consumables from the printer.
  2. Inspect the release texture for contamination.
  3. Follow the instructions for cleaning the release texture.
  4. The underside of the LPU can also become contaminated, particularly if the LPU fan filter is clogged. If you suspect that the underside of the LPU is contaminated rather than the release texture, test the LPU and Backlight Unit, then clean the LPU and LPU fan filter based on the results.

The optical surface most likely to be contaminated is the glass optical window, which sits atop the Light Processing Unit (LPU).

  1. With the printer plugged in and powered on, tap the wrench icon to access the Settings screen, then tap Maintenance > Motor Moves. The Motor Moves screen appears. Tap and hold Left (<) to move the LPU housing to the middle of the printer cavity. Other controls on this screen fully sweep the LPU housing across the printer cavity and control the build platform carriage.
  2. When prompted by the touchscreen, disconnect the power cable before continuing with maintenance.
  3. Inspect the optical window for contamination.
  4. Follow the instructions for cleaning the glass optical window.
  5. If streaks are difficult to remove, contact Formlabs Support or your authorized reseller.

The optical surface most likely to be contaminated is the glass optical window beneath the resin tank that protects internal components from contamination.

  1. Inspect the optical window on the Form 2 or for contamination.
  2. Follow the instructions in Cleaning the glass optical window (Form 2). If streaks are difficult to remove, contact Formlabs Support or your authorized reseller.

Avviso:

Segui alla lettera le istruzioni per pulire le superfici ottiche. La mancata osservazione di queste istruzioni può comportare danni alla stampante.

Step 5: Check the build platform

A loose build platform can cause delamination in prints.

On Form 4 generation printers, the build platform mounts on the build platform dovetail assembly, which includes the build platform latch. Any issues with the dovetail assembly may cause alignment issues for the build platform and the LPU surface.

  1. Utilizza una chiave da 4 mm o un altro strumento adatto per stringere la barra di trazione sul lato inferiore dell'assemblaggio a coda di rondine della piattaforma di stampa di mezzo giro.
  2. Inserisci una piattaforma di stampa, abbassa la chiusura della piattaforma di stampa e prova a spostare la piattaforma di stampa a mano per vedere se è allentata.
    • Se la piattaforma di stampa è ancora allentata, stringi la barra di trazione di un altro mezzo giro e testa nuovamente la piattaforma di stampa.
    • Se la chiusura della piattaforma di stampa è troppo stretta per chiudersi completamente, allenta leggermente la barra di trazione e prova nuovamente la piattaforma di stampa.
  3. Allinea la piattaforma di stampa prima di provare a stampare di nuovo.
  4. Se il problema persiste, in particolare se è stato risolto temporaneamente stringendo la coda di rondine della piattaforma di stampa, sostituisci l'assemblaggio a coda di rondine. Gli assemblaggi a coda di rondine di ricambio sono disponibili per l'acquisto sul negozio Formlabs. Segui la guida Sostituzione dell'assemblaggio a coda di rondine della piattaforma di stampa della Form 4 per sostituire il componente.
Barra di trazione per l'attacco a coda di rondine della piattaforma di stampa della Form 4
  1. Make sure the build platform is locked in place.
  2. Hold the build platform and gently rock it back and forth.
  3. If the build platform rotates or moves when the cam handle is locked, contact Formlabs Support or your authorized reseller for instructions to resolve this issue.
  1. Make sure the build platform is locked in place.
  2. Hold the build platform and gently rock it back and forth.
  3. If the build platform rotates or moves when the cam handle is locked, contact Formlabs Support or your authorized reseller for instructions to resolve this issue.

Contattare l'Assistenza Formlabs

Contatta l'Assistenza Formlabs o il tuo rivenditore autorizzato se i passaggi sopra descritti non ti consentono di risolvere l'errore di stampa.

Per aiutarci a fornirti una risposta rapida ed efficace, segui questi passaggi:

  1. Carica i dati di diagnostica
  2. Nome di serie della stampante
    • Il nome di serie si trova sul pannello posteriore della stampante nel formato AggettivoAnimale o Macchina-AggettivoAnimale.
    • Stampante della generazione Form 4 o Form 4L: tocca Settings (Impostazioni) > General (Generali) > About this printer (Informazioni su questa stampante)
    • Stampante della generazione Form 3 o Form 3L: tocca l'icona della stampante nella schermata Home.
    • Form 2: tocca l'icona della stampante nella schermata iniziale. Apparirà la schermata Your Printer (La tua stampante).
  3. Passaggi eseguiti nel tentativo di risolvere il problema
    • Esempio: "Ho cambiato l'orientamento del modello in PreForm. Ho anche ispezionato il serbatoio resina, ma non ho notato danni, opacizzazione o residui."
  4. Formulazione della resina e numero di lotto
  5. Spessore dello strato (μm)
    • Form 2: tocca l'icona della coda nella schermata iniziale. Verrà visualizzata la schermata Jobs (Progetti).
    • Altre stampanti SLA Formlabs: tocca l'icona della coda di stampa sull'interfaccia touchscreen della stampante. Comparirà la schermata Queue (Coda) o Jobs (Lavori).
  6. File FORM pertinenti
    • Se disponibili, allega alla richiesta di assistenza i file FORM del modello.
  7. Precedenti tentativi di stampa della parte e stampe riuscite
    • Esempio: "In precedenza ho stampato il file part2.form tre volte. La prima e la seconda stampa sono andate a buon fine. La terza non è riuscita."